Wire-mesh and X-ray microtomography studies of flow patterns in the mixing chamber of an effervescent atomizer
Wire-mesh and X-ray microtomography studies of flow patterns in the mixing chamber of an effervescent atomizer
Otahal, J.; Boden, S.; Schleicher, E.; Beyer, M.; Jícha, M.; Hampel, U.
Abstract
We performed wire-mesh and X-ray micro¬tomography studies of the two-phase flow in the mixing chamber of an effervescent atomizer. Flow patterns in the mixing chamber can be revealed by the miniature wire mesh sensor with a temporal resolution of 10 kHz whereas microtomography provides accurate and high-resolution axial-radial gas fraction profiles. The paper describes both measurement techniques and first results of experimental investigation.
Keywords: Two-phase flow; wire mesh sensor; X-ray microtomography
-
Beitrag zu Proceedings
5th International Symposium on Process Tomography, 25.-26.08.2008, Zakopane, Poland
Proceedings of the 5th International Symposium on Process Tomography, Paper No. PT08_cr8 -
Vortrag (Konferenzbeitrag)
5th International Symposium on Process Tomography, 25.-26.08.2008, Zakopane, Poland
Permalink: https://www.hzdr.de/publications/Publ-11231