Ueberholz, K.; Bozyk, L.; Bussmann, M.; Eizenhöfer, N.; Hannen, V.; Horst, M.; Kiefer, D.; Kiefer, N.; Klammes, S.; Kühl, T.; Langfeld, B.; Löser, M.; Ma, X.; Nörtershäuser, W.; Sánchez, R.; Schramm, U.; Siebold, M.; Spiller, P.; Steck, M.; Stöhlker, T.; Walther, T.; Wang, H.; Weinheimer, C.; Wen, W.; Winters, D.

Abstract

An improved moveable in vacuo XUV fluorescence detection system was employed for the laser cooling of bunched relativistic (β = 0.47) carbon ions at the Experimental Storage Ring (ESR) of GSI Helmholtzzentrum Darmstadt, Germany. Strongly Doppler boosted XUV fluorescence (∼90 nm) was emitted from the ions in a forward light cone after laser excitation of the 2s–2p transition (∼155 nm) by a new tunable pulsed UV laser system (257 nm). It was shown that the detected fluorescence strongly depends on the position of the detector around the bunched ion beam and on the delay (∼ns) between the ion bunches and the laser pulses. In addition, the fluorescence information could be directly combined with the revolution frequencies of the ions (and their longitudinal momentum spread), which were recorded using the Schottky resonator at the ESR. These fluorescence detection features are required for future laser cooling experiments at highly relativistic energies (up to γ∼ 13) and high intensities (up to 1011 particles) of ion beams in the new heavy ion synchrotron SIS100 at FAIR.

Permalink: https://www.hzdr.de/publications/Publ-36964