Condensation in Horizontal Heat Exchanger Tubes


Condensation in Horizontal Heat Exchanger Tubes

Leyer, S.; Zacharias, T.; Maisberger, F.; Lamm, M.; Vallee, C.; Beyer, M.; Hampel, U.

Abstract

Many innovative reactor concepts for Generation III nuclear power plants use passive safety equipment for residual heat removal. These systems use two phase natural circulation. Heat transfer to the coolant results in a density difference providing the driving head for the required mass flow. By balancing the pressure drop the system finds its operational mode. Therefore the systems depend on a strong link between heat transfer and pressure drop determining the mass flow through the system. In order to be able to analyze these kind of systems with the help of state of the art computer codes the implemented numerical models for heat transfer, pressure drop or two phase flow structure must be able to predict the system performance in a wide parameter range. Goal of the program is to optimize the numerical models and therefore the performance of computer codes analyzing passive systems. Within the project the heat transfer capacity of a heat exchanger tube will be investigated. Therefore the tube will be equipped with detectors, both temperature and pressure, in several directions perpendicular to the tube axis to be able to resolve the angular heat transfer. In parallel the flow structure of a two phase flow inside and along the tube will be detected with the help of x-ray tomography. The water cooling outside of the tube will be realized by forced convection. It will be possible to combine the flow structure measurement with an angular resolved heat transfer for a wide parameter range. The test rig is set up at the TOPLFOW facility at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR), so that it will be possible to vary the pressure between 5 and 70 bar. The steam mass content will be varied between 0 and 100 percent. The results will be compared to the large scaled Emergency Condenser Tests performed at the INKA test facility in Karlstein (Germany). The paper will explain the test setup and the status of the project will be presented.

Keywords: emergency condenser; passive safety systems; steam condensation

Beteiligte Forschungsanlagen

  • TOPFLOW-Anlage
  • Vortrag (Konferenzbeitrag)
    2012 International Congress on the Advances in Nuclear Power Plants, 24.-28.06.2012, Chicago, USA
  • Beitrag zu Proceedings
    2012 International Congress on the Advances of Nuclear Power Plants, 24.-28.06.2012, Chicago, USA
    Conference Proceedings, Paper No. 12334

Permalink: https://www.hzdr.de/publications/Publ-17550