Effects of inlet condition on flows structure of bubbly flow in a rectangular column


Effects of inlet condition on flows structure of bubbly flow in a rectangular column

Akbar, M. H. B. M.; Hayashi, K.; Lucas, D.; Tomiyama, A.

Abstract

Experiments on bubbly flows in a rectangular column are carried out to investigate effects of inlet condition on flow structure. An air diffuser having 35 nozzles is used. The inlet gas flow rates from 34 nozzles are uniform and the lift coefficients of bubbles are small at this flow rate, whereas the gas inflow from the remaining one nozzle is varied to change the sign and magnitude of lift coefficients. The main conclusions obtained are as follows: (1) bubbly flow in a bubble column is apt to be heterogeneous even with small non-uniformity in the distribution of gas inflow, (2) when the nozzle causing non-uniform gas inflow is located in the center of the diffuser plate and the inflow distribution is symmetric, heterogeneous structure is formed due to the lift-induced flow instability pointed out by Lucas et al., (3) when the nozzle causing non-uniform gas inflow is located near the side wall of the column and the inflow distribution is asymmetric, heterogeneous structure is induced by the Coanda effect, and (4) the effects of inlet condition on flow structure in a bubble column can be predicted using a multi-fluid model.

Keywords: Instability; Bubble; Bubble column; Inlet condition; Lift force; Multi-fluid model

Permalink: https://www.hzdr.de/publications/Publ-19179