Publikationsrepositorium - Helmholtz-Zentrum Dresden-Rossendorf
2 PublikationenRF performance results of the 2nd ELBE SRF gun
Arnold, A.; Freitag, M.; Lu, P.; Murcek, P.; Teichert, J.; Vennekate, H.; Xiang, R.; Kneisel, P.; Ciovati, G.; Turlington, L.
Abstract
An improved SRF gun (ELBE SRF gun II) has been installed and commissioned at HZDR. This new gun replaced the first SRF gun of the ELBE accelerator which had been in operation since 2007. The new gun has an improved 3.5-cell niobium cavity those SRF performances have been studied first with a copper cathode. After the replacement by our standard Cs2Tecathode we observed a tremendous degradation of the cavity gradient paired with an increase of field emission. In this contribution we will report on our in-situ investigations to find the origin and the reason for the particle contamination that happened during the first cathode transfer.
Keywords: SRF gun; photo electron source; injector; ELBE; superconducting RF
Beteiligte Forschungsanlagen
- Strahlungsquelle ELBE DOI: 10.17815/jlsrf-2-58
Verknüpfte Publikationen
- DOI: 10.17815/jlsrf-2-58 is cited by this (Id 22470) publication
-
Poster
7th International Conference on RF Superconductivity, SRF 2015, 13.-18.09.2015, Whistler, British Columbia, Canada -
Beitrag zu Proceedings
7th International Conference on RF Superconductivity, SRF 2015, 13.-18.09.2015, Whistler, British Columbia, Canada
Proceedings of the 7th International Conference on RF Superconductivity: Joint Accelerator Conferences Website (JACoW)
Downloads
Permalink: https://www.hzdr.de/publications/Publ-22470