Investigation of the LET-dependency from BeO using single photon detection for dosimetry in proton beams


Investigation of the LET-dependency from BeO using single photon detection for dosimetry in proton beams

Radtke, J.; Kormoll, T.; Grabs, L.; Lutz, B.; Lühr, A.; Ullrich, W.; Sponner, J.; Henniger, J.

Abstract

Optically stimulated luminescence (OSL) is gaining greater importance in the field of personal dosimetry in the last few years. Its principle is based on the release of small amounts of light induced by the prior absorption of ionizing radiation. One suitable luminophore for OSL is beryllium oxide (BeO). Because of its near tissue equivalent effective atomic number of 7, it is excellent for personal dosimetry. Furthermore, the luminescence signal has a wide dose linearity ranging from the µGy region up to few Gy. For this reason, this ceramic can be used for several different areas of application. A new generation of measurement systems based on the OSL of BeO, which has a very low OSL light intensity, was developed by the radiation physics group at TU Dresden. This property allows single photon detection which is superior in contrast to other detection methods. Therefore, a single photon sensor was used as a detector. The single photon mode of the detector in combination with the so called timestamp detection method allows accessing the greatest possible information of the OSL light. This work applies the new system to dosimetry of a proton beam. Because of the LET-dependencies of the luminescence light, this presents a challenge. Common problems of solid state dosimetry are local saturation effects, which were investigated for BeO. Opportunities for correction in terms of the LET-dependency of the luminophore are being discussed. For the empirical determination of the behavior of BeO in proton beams, measurements at the medical proton therapy facility at the University Proton Therapy Dresden (UPTD) were carried out. All collected data were analyzed for LET-dependency on the response signal. For the measurements, BeO ceramics were placed at different depth infront and inside the spread out Bragg peak (SOBP). The dose read from dosimeters was analyzed with respect to the applied dose and the LET. All measurements infront of the SOBP shows no deviation of the estimated dose. The dose determination in the SOBP yielded an underestimation by 15%. This is object of current investigation.

  • Poster
    Jahrestagung der biomedizinischen Technik und Dreiländertagung der medizinischen Physik, 10.-13.09.2017, Dresden, Deutschland

Permalink: https://www.hzdr.de/publications/Publ-25983