UHV Photocathode Plug Transfer Chain for the BERLinPro SRF-Photoinjector


UHV Photocathode Plug Transfer Chain for the BERLinPro SRF-Photoinjector

Kühn, J.; Borninkhof, J.; Bürger, M.; Frahm, A.; Jankowiak, A.; Kamps, T.; Schmeißer, M. A. H.; Schuster, M.; Murcek, P.; Teichert, J.; Xiang, R.

Abstract

A dedicated particle free UHV photocathode plug transfer chain from the preparation system to the SRF-Photoinjector was set up and commissioned at HZB for the bERLinPro project. The plug handling system was designed in collaboration with the ELBE team at HZDR, where the same transfer chain is in commissioning phase. In the future the exchange of photocathodes between the laboratories offers the possibility to test different types of photocathodes in different SRF-photoinjectors.

Keywords: photocathode SRF-photoinjector; electron source; plug transfer

Beteiligte Forschungsanlagen

Verknüpfte Publikationen

  • Poster
    IPAC 2017 - 8th International Particle Accelerator Conference, 14.-19.05.2017, Copenhagen, Denmark
  • Open Access Logo Beitrag zu Proceedings
    IPAC 2017 - 8th International Particle Accelerator Conference, 14.-19.05.2017, Copenhagen, Denmark
    Proceedings of the 8th International Particle Accelerator Conference, Genf: JACoW

Permalink: https://www.hzdr.de/publications/Publ-26694